Rockwell Automation 20-COMM-P Profibus Adapter User Manual
Page 38
4-8
Configuring the Profibus Scanner
Logic Command/ Status, Reference / Feedback, Datalinks and Parameter
Access (explicit messaging) modules are added using the Modules tab.
10. Click on the Modules tab. Click Add to view the choice of modules.
Figure 4.12 20-COMM-P Modules Tab
In our example, Station 1 will be controlled using Logic Command /
Status and Reference / Feedback. The PowerFlex 70 utilizes 16-bit
Reference / Feedback (2 bytes).
11. Select “Ctrl/Stat & Ref/Fdbk (2+2bytes)” from the “Available
Modules” list as shown in
. Click OK.
Figure 4.13 Available Modules: Ctrl/Stat & Ref/Fdbk (2x2 bytes) Window
12. The “Ctrl/Stat & Ref/Fdbk” (2+2 bytes) module has now been added
as shown in
20COMM-UM006A-EN-P.book Page 8 Friday, September 28, 2001 10:43 AM