Using I/O Messaging

5-7

Parameter Settings

Scanner Settings

An SST-PFB-SLC scanner is in slot 1 of the SLC rack and configured as
Station 0. The Advanced I/O Configuration is setup per

Figure 5.3

.

Figure 5.3 Advanced I/O Configuration

Device

Parameter

Name

Value

Description

PowerFlex 70

90

Speed Ref A Sel

22

‘DPI Port 5’ (20-COMM-P)

300

Data In A1

140

Points to Pr. 140 [Accel Time 1]

301

Data In A2

142

Points to Pr. 142 [Decel Time 1]

302

Data In B1

100

Points to Pr. 100 [Jog Speed]

303

Data In B2

155

Points to Pr. 155 [Stop Mode A]

304

Data In C1

101

Points to Pr. 101 [Preset Speed 1]

305

Data In C2

102

Points to Pr. 102 [Preset Speed 2]

306

Data In D1

103

Points to Pr. 103 [Preset Speed 3]

307

Data In D2

104

Points to Pr. 104 [Preset Speed 4]

310

Data Out A1

140

Points to Pr. 140 [Accel Time 1]

311

Data Out A2

142

Points to Pr. 142 [Decel Time 1]

312

Data Out B1

100

Points to Pr. 100 [Jog Speed]

313

Data Out B2

155

Points to Pr. 155 [Stop Mode A]

314

Data Out C1

101

Points to Pr. 101 [Preset Speed 1]

315

Data Out C2

102

Points to Pr. 102 [Preset Speed 2]

316

Data Out D1

103

Points to Pr. 103 [Preset Speed 3]

317

Data Out D2

104

Points to Pr. 104 [Preset Speed 4]

20-COMM-P

11

DPI I/O Config

xxx1 1111

Enables Cmd/Ref, Datalinks A-D