Logic status word – Rockwell Automation 20-750-CNETC PowerFlex Coaxial ControlNet Option Module User Manual

Page 136

Advertising
background image

136

Rockwell Automation Publication 750COM-UM003B-EN-P - November 2012

Appendix D

Logic Command/Status Words: PowerFlex 750-Series Drives

Logic Status Word

Logic Bits

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10

9

8

7

6

5

4

3

2

1

0

Command

Description

x

Run Ready

0 = Not Ready to Run
1 = Ready to Run

x

Active

0 = Not Active
1 = Active

x

Command Direction

0 = Reverse
1 = Forward

x

Actual Direction

0 = Reverse
1 = Forward

x

Accelerating

0 = Not Accelerating
1 = Accelerating

x

Decelerating

0 = Not Decelerating
1 = Decelerating

x

Alarm

0 = No Alarm (Par. 959 and 960)
1 = Alarm

x

Fault

0 = No Fault (Par. 952 and 953)
1 = Fault

x

At Setpt Spd

0 = Not at Setpoint Speed
1 = At Setpoint Speed

x

Manual

0 = Manual Mode Not Active
1 = Manual Mode Active

x

Spd Ref ID 0

00000 = Reserved
00001 = Auto Ref A (Par. 545)
00010 = Auto Ref B (Par. 550)
00011 = Auto Preset Speed 3 (Par. 573)
00100 = Auto Preset Speed 4 (Par. 574)
00101 = Auto Preset Speed 5 (Par. 575)
00110 = Auto Preset Speed 6 (Par. 576)
00111 = Auto Preset Speed 7 (Par. 577)
01000 = Reserved
01001 = Reserved
01010 = Reserved
01011 = Reserved
01100 = Reserved
01101 = Reserved
01110 = Reserved
01111 = Reserved
10000 = Man Port 0
10001 = Man Port 1
10010 = Man Port 2
10011 = Man Port 3
10100 = Man Port 4
10101 = Man Port 5
10110 = Man Port 6
10111 = Reserved
11000 = Reserved
11001 = Reserved
11010 = Reserved
11011 = Reserved
11100 = Reserved
11101 = Man Port 13 (embedded ENET)
11110 = Man Port 14 (Drive Logix)
11111 = Alternate Man Ref Sel

x

Spd Ref ID 1

x

Spd Ref ID 2

x

Spd Ref ID 3

x

Spd Ref ID 4

x

Reserved

x

Running

0 = Not Running
1 = Running

x

Jogging

0 = Not Jogging (Par. 556 and 557)
1 = Jogging

x

Stopping

0 = Not Stopping
1 = Stopping

x

DC Brake

0 = Not DC Brake
1 = DC Brake

x

DB Active

0 = Not Dynamic Brake Active
1 = Dynamic Brake Active

x

Speed Mode

0 = Not Speed Mode (Par. 309)
1 = Speed Mode

x

Position Mode

0 = Not Position Mode (Par. 309)
1 = Position Mode

x

Torque Mode

0 = Not Torque Mode (Par. 309)
1 = Torque Mode

x

At Zero Speed

0 = Not at Zero Speed
1 =At Zero Speed

x

At Home

0 = Not at Home
1 = At Home

x

At Limit

0 = Not at Limit
1 = At Limit

x

Current Limit

0 = Not at Current Limit
1 = At Current Limit

x

Bus Freq Reg

0 = Not Bus Freq Reg
1 = Bus Freq Reg

x

Enable On

0 = Not Enable On
1 = Enable On

x

Motor Overload

0 = Not Motor Overload
1 = Motor Overload

x

Regen

0 = Not Regen
1= Regen

Advertising