22 How to Install Your Analog Module

Mounting the Analog Module on the Terminal Base Unit

1. Rotate the keyswitch (1) on the terminal base unit (2) clockwise

to the position required for the specific type of analog module.

Figure 2.4

2. Make certain the flexbus connector (3) is pushed all the way to

the left to connect with the neighboring terminal base/adapter.
You cannot install the module unless the connector is fully
extended.

3. Make sure that the pins on the bottom of the module are straight

so they will align properly with the connector in the terminal
base unit.

4. Position the module (4) with its alignment bar (5) aligned with

the groove (6) on the terminal base.

5. Press firmly and evenly to seat the module in the terminal base

unit. The module is seated when the latching mechanism (7) is
locked into the module.

4

1

3

2

5

6

7

Analog Module Catalog Number

Keyswitch Position

1794-IF4I, 1794-IF4IXT, 1794-IF4ICFXT

3

1794-OF4I, 1794-OF4IXT

4

1794-IF2XOF2I, 1794-IF2XOF2IXT

5