Publication 1794-6.5.8 - January 2010

Module Programming 43

Figure 1.8

SLC Programming for the 1794-IF4I Isolated Analog Input Module

PowerUp Bit

0000

Program Action

S2:1

15

BTR_CONTROL

COP

COPY FILE
SOURCE
DEST

#B3:100

#M0:1.100

LENGTH

3

BTW_CONTROL

COP

COPY FILE
SOURCE
DEST

#B3:110

#M0:1.200

LENGTH

3

COP

COPY FILE
SOURCE
DEST

#M1:1.100

#B3:0

LENGTH

4

0001

BTR PENDING

B3:5

0

This rung configures the block transfer operation
type, length, and RIO address at power-up. Bit
B3:100/7 must be set to 1 to indicate a BTR and
bit B3:110/7 must be 0 to indicate a BTW.

U

BTR DONE BIT

B3:0

1

CHECK BTR ST ATUS

B3:5

1

BTR ERROR BIT

B3:0

12

0002

B3:5

1

COP

COPY FILE
SOURCE
DEST

#M1:1.200

#B3:10

LENGTH

4

0003

BTW PENDING

B3:15

0

CHECK BTW ST ATUS

B3:15

1

BTR status is copied to the B3:0 area when a BTR
is in progress.

Unlatch the bit that continues to check the BTR status.

BTW status is copied to the B3:100 area when a
BTW is in progress.

To next page.