Configuration data table – Rockwell Automation 1747-KE,D17476.12 DH-485/RS-232C Interface Module User Manual
Page 101

Publication 1747-UM005B-EN-P - March 2006
Application Examples 8-13
Configuration Data Table
Shown below is the configuration information for N10 in Decimal
radix.
Configuration Data Table
I:1.0
Turn OFF handshake
bit to interface
module.
Rung
2:3
COP
COPY
Source
#I:1.0
Dest
#N10:10
Length
8
14
] [
O:1.0
Reset 40 second base
timer.
This rung checks that proper data was echoed from the module,
or that 5 seconds passed without interface module response.
Get data from the
interface module.
T4:0
Check the first
word echoed.
( )
O:1.0
14
U
14
] [
I:1.0
14
] [
O:1.0
14
]/[
7
] [
S:4
NEQ
NOT EQUAL
Source A
N10:11
0
Source B
N10:1
123
Handshake
bit to
module.
Handshake
bit from
module.
Handshake
bit to the
interface
module.
No response
from
interface
module.
Set 5 secs
after data
echo.
Check the last
word echoed.
NEQ
NOT EQUAL
Source A
N10:17
0
Source B
N10:7
654
(RES)
Turn ON interface
Reset bit.
( )
O:1.0
12
L
Rung
2:4
<END>
Address 0
1
2
3
4
5
6
7
8
9
N10:0
6
XXX
456
789
345
678
321
654
0
0
N10:10
0
0
0
0
0
0
0
0
0
0
N10:20
0
0
0
0
0
0
0
0
0
0