6-14 Module Configuration Using the Backplane

Modem Init String for Characters 1 Through 14

To set up string characters 1 to 14, build the configuration in the table
shown below. Please note that sending a ~ character produces a one
second wait on the modem.

Follow the configuration instructions found on page 6-2.

SLC Output File to the Interface Module

Bit

Word

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

0

(1)

Module
Mode
Bit

Data
Hand
shake
Bit

Read or
write
Bit

Reset
Interface
Module
Bit

Reserved

Data ID=4

1

1st ASCII character

2nd ASCII character

2

3rd ASCII character

4th ASCII character

3

5th ASCII character

6th ASCII character

4

7th ASCII character

8th ASCII character

5

9th ASCII character

10th ASCII character

6

11th ASCII character

12th ASCII character

7

13th ASCII character

14th ASCII character

(1)

The output status word is defined on page 6-6. To configure the Modem Init String, the Read or Write Bit must be at 0 and the Module Mode Bit must be
at 1. To read the Modem Init String, the Read or Write Bit must be 1 and the Module Mode Bit can be either 0 or 1.