Maximum communication distances – Rockwell Automation 1747-KE,D17476.12 DH-485/RS-232C Interface Module User Manual

Page 119

Advertising
background image

Publication 1747-UM005B-EN-P - March 2006

Specifications A-3

Maximum Communication Distances

Maximum Communication Distances

Communication

Max. Distance Allowed in m (ft)

Rate (Kbps)

RS-232

RS-423

RS-422

RS-485

300

15 (50)

1230 (4000)

1230 (4000)

1230 (4000)

600

15 (50)

920 (3000)

1230 (4000)

1230 (4000)

1200

15 (50)

770 (2500)

1230 (4000)

1230 (4000)

2400

15 (50)

502 (1650)

1230 (4000)

1230 (4000)

4800

15 (50)

245 (800)

1230 (4000)

1230 (4000)

9600

15 (50)

120 (400)

1230 (4000)

1230 (4000)

19200

15 (50)

60 (200)

1230 (4000)

1230 (4000)

IMPORTANT

When communicating in RS-232 mode, use the
RS-423 jumper settings.

When communicating in RS-423 mode, use RS-423 or
compatible receivers.