5-4 Module Configuration Using an ASCII Terminal

Top Level Setup Menu

The Top Level Setup Menu provides six selections.

Top Level Setup Menu

• To redisplay the above menu, press [ENTER]

.

• To access the corresponding menus (described on the following

pages), press [1] through [5].

• To save changes and exit, press [X]. This enables the DH-485

and DF1 ports.

Change Parameters for Menus 1 through 4

To change any of the parameters in menus 1 through 4:

1. Select the parameter you wish to change. The current parameter

setting and a prompt for entering a new value appear at the
bottom of the screen.

2. Type in the new value and press [ENTER].

If you enter an invalid value, the ASCII terminal beeps and the
prompt remains. Refer to the tables on pages 5-5 through 5-12
for the valid parameter options.

IMPORTANT

After configuration is complete, place the module in
Run mode as described on page 4-15.

If you operate the module in Configuration mode,
cycling power will disable the DF1 and DH-485
ports, return to the configuration mode, and display
the Top Level Setup Menu on your ASCII terminal.

1. CONFIG PORT
2. DF1 PORT
3. DH 485 PORT
4. DF1 PROTOCOL
5. DISPLA Y PARAMETERS
X. SAVE AND EXIT

Enter Selection. . . . .