Chapter 1

Introducing the Control Coprocessor

1-3

Table 1.B describes the hardware elements for the main module.

Table 1.B

MainĆModule Hardware Elements

Hardware

Element

Description

RESET Switch

Use the reset switch to reinitialize the control coprocessor
When the serial expander module is installed, use the keyswitch to reinitialize the coprocessor

LEDs

Four status indicators provide information on the CPU, COMM0 port, COMM1 port, and battery

COMM0 Port

This is a 9Ćpin, optically isolated, serial communication port that supports communication

defined by EIA RSĆ232C standards
Use this port to connect:

personal computers

terminals

other peripheral devices

COMM1 Port

This is a 25Ćpin, optically isolated, serial communication port that supports communication

defined by EIA RSĆ232C, Ć423, and Ć485 standards
You can also use this port with most RSĆ422A equipment as long as:

termination resistors are not used

the distance and transmission rate are reduced to 200 ft at 19.2 kbps

Use this communication port to connect peripheral devices such as:

personal computers

terminals

barĆcode readers

weigh scales

printers

Battery

This battery provides backup power for control coprocessor memory during power failure or

normal down time
Use the 3.0 volt lithium battery (cat. no. 1770ĆXYC) that is provided with your coprocessor

Ethernet Port

(1771ĆDMC1 and

1771ĆDMC4 only)

The 1771ĆDMC1 and 1771ĆDMC4 versions of the control coprocessor include an Ethernet

communication port that connects to thickĆwire, thinĆwire, or twistedĆpair networks via a standard

15Ćpin transceiver connection
These modules use TCP/IP protocol and have resident FTP and TELNET utilities
You can program client/server applications for an Ethernet port using the TCP/IP socket library;

an Internet socket library is supplied with the PCBridge software
A downloadable driver is also availableĊas a part of the PCBridge softwareĊthat provides

INTERCHANGE

t

server functionality; when the coprocessor is attached to a standard PLCĆ5

processor, this provides Ethernet connectivity

Optional RAM

You can install additional RAM in the main module to expand user memory
The following single inline memory modules (SIMMs) are available:

Memory Size

Catalog Number

256 Kbytes

1771ĆDRS

1 Mbyte

1771ĆDRS1

4 Mbytes

1771ĆDRS4