Summary of Changes

i

Summary of Changes

This edition of this publication contains new and updated information.

To help you find new and updated information in this manual, we have
included change bars as shown to the left of this paragraph.

New Information

For detailed information on this subject:

See:

Three new function calls were added to the API library:

DTL_READ_W_IDX

DTL_RMW_W_IDX

DTL_WRITE_W_IDX

Appendix B

Two new Ethernet

R

communication features were added. You can now:

send/receive communication using AllenĆ Bradley's INTERCHANGEt

software and the INTERD daemon

use the SNMPD daemon

Chapter 6

Updated Information

For detailed information on this subject:

See:

All of the COMM ports on the coprocessor and expander are no longer

initialized at the factory for connection to a terminal. The 9Ćpin serial port

COMM 0, used for configuring the coprocessor, retains the factory settings

for connection to a programming terminal. In Series A Revision E (1.30)

and later of the firmware, however, COMM1, COMM2, and COMM3 have

all of their serialĆport settings prepared for raw binary data transfers.

Chapter 7

The control coprocessor and the expander now provide solid support for

RSĆ485 communications. The modules now have the necessary

hardware and lowĆlevel drivers on COMM1, COMM2, and COMM3.