Cable length requirements, Cable configurations – Rockwell Automation 1771-DMC_DMC1_DMC4_DXPS Control Coprocessor User Manual User Manual

Page 277

Advertising
background image

Cable Connections

Appendix C

C-4

Cable Length Requirements

Refer to Table C.C for information on the cable lengths that you can use
with the serial COMM1, COMM2, and COMM3 ports.

Table C.C

COMM1, COMM2, and COMM3 Maximum Cable Length

RS Communication

Transmission Rate

Maximum Cable Length

232C

all

15 m (50 ft)

422 (compatible)

19.2 kbps

61 m (200 ft)

423

9600

61 m (200 ft)

485

all

1.2 Km (4000 ft)

Cable Configurations

See Figure C.3 for an example cable configuration.

Figure C.3

Cable for a 9ĆPin IBM PC/AT, T50, T60, or T47 Computer

to the Control Coprocessor 25ĆPin COMM1, 2, or 3 Port

5

7
8
6
1
4

25

14

13

1

1
5

6
9

3
2

7

5
4

20

8
6

3
2

9

Common
RXD
TXD
CTS
RTS
DTR
CD
DSR

Common

TXD

RXD

RTS
CTS

DSR

CD

DTR

N/C

Shell shield

Shell shield

x.x m

(x.xx ft.)

1

1

See Table C.C for maximum cable lengths for the COMM1, COMM2, and COMM3 ports.