1738-vhsc 24v dc high speed counter module, D-12, Message size: 6 bytes – Rockwell Automation 1738-ADNX ArmorPoint I/O DeviceNet Adapters User Manual

Page 122

Advertising
background image

Publication 1738-UM001A-EN-P - February 2005

D-12 Default Data Maps

1738-VHSC 24V dc High Speed Counter Module

Message size: 6 Bytes

1738-SSI Synchronous Serial Interface Absolute

Encoder Module

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

Produces (scanner Rx)

Channel 0 value of present counter state (LSW)

Channel 0 value of present counter state (MSW)

PE

EF

NR

0

FS

FS

OS

OS

0

ZS

BS

AS

C1

C0

ZD

0

Where: PE = Programming error

EF = EEPROM fault status

NR = Not ready status bit

FS = Output fault status bit - bit 10 for output 0, bit 11 for output 1

OS = Output on/off status bit - bit 8 for output 0, bit 9 for output 1

ZS = Z input status

BS = B input status

AS = A input status

C = Stored data count

ZD = Zero frequency detected

LSW = Least significant word

MSW = Most significant word

7

6

5

4

3

2

1

0

Produce 8

C2ST

C1ST

C2R

C1R

INC

DEC

RUN

I1

Status Byte 0

1

Produce 9

RES

RES

RES

LHON

IDF

2

CCE

CCF

SPF

Status Byte 1

1

1.

For detailed descriptions of these bits, see 1738-SSI User Manual, publication 1738-UM009.

2.

Monitor IDF to determine the validity of the produced data. If IDF=1, the SSI data is false.

7

6

5

4

3

2

1

0

Consume 0

RES

RES

RES

SCMP2

SCMP1

CC2

CC1

LACK

Master ACK
Byte

1, 3

Consume 1

RES

RES

RES

RES

RES

RES

RES

RES

CONS1

1

3.

The master must provide the Master ACK Byte in order to receive the polled Produced bytes 0-9.