Sample programs appendix a – Rockwell Automation 1785-BCM_BEM, D17856.5.4 PLC-5 Backup Communication Module User Manual User Manual

Page 147

Advertising
background image

Sample Programs

Appendix A

A-29

Table A.C
Data Table Typical Transfer Time Using Method 2 Program
with Minimal Progam Scan (4–9 ms)

Number of Blocks
Being Transferred

Number of Words

Being Transferred

Transfer Time (in ms)
for Series A BCM
(see notes 1 & 2)

Transfer Time (in ms)
for Series B BCM
Fast Transfer Mode
Enabled (see notes 1,
3, & 4)

1

62

170–250

60–80

3

186

200–300

90–120

7

434

350–500

130–180

10

620

350–600

170–230

16

992

400–1000

180–260

5

32

1984

320–720

6

64

3968

700–1400

7

1

These times do not significantly change with program scan, but as the number of blocks increase
so does program scan.

2

Times were taken using a PLC-5/25 processor.

3

Series B BCM module with fast mode disabled is approximately 50% slower than the times
shown.

4

Times were taken using a PLC-5/40 processor with one channel configured for DH+ and three
channels configured for remote I/O scanner at 230 kbaud.

5

Program scan 12–16 ms.

6

Program scan 20–25 ms.

7

Program scan 30–35 ms.