Rockwell Automation Publication 1788-UM057B-EN-P - September 2014

45

Set Up in the Studio 5000 Logix Designer Application

Chapter 2

Redundant Master Mismatch

If the two masters are not synchronized (for example, there is a configuration
mismatch) one of the following errors on the back-up LAS is displayed.

• Master + Device Config Mismatch

indicates that there is a difference

between the LAS and back-up LAS master configuration.

• Device Config Mismatch

indicates that there is a difference in at least one

of the field devices between the LAS and back-up LAS configuration.

Redundant Master Disabled

If a redundant master is not in use, the Multi-Master status is disabled.