3-12

Configuring the Module

6. Double-clicking on Controller Tags or Program Tags in the menu

tree will display the various tags, including the tags for the
1769-SM1 module (

Figure 3.14

). Click on the Monitor Tags tab at

the bottom of the window to enter the configuration data.

Figure 3.14 Controller Tags Screen

The CompactLogix controller will download the configuration data to
the 1769-SM1 module on power-up.

TIP: RSLogix 5000 creates a data array that is much larger than the 60
words previously specified when the module was configured. Use words
0 - 59 and ignore words 60 - 197. Also, note the data entry format in

Figure 3.14

is hexadecimal (16#). To change the format, click on the

appropriate field in the “Style” column.