Resetting the module – Rockwell Automation 1769-SM1 Compact I/O to DPI/SCANport Module User Manual
Page 47
 
Configuring the Module
3-17
To set the fault configuration parameters
If you set Parameter 09 - [Idle Action 1], 26 - [Idle Action 2], or 43 - 
[Idle Action 3] to “Send Flt Cfg,” the values in the following 1769-SM1 
module parameters are sent to the drive after an idle action occurs. You 
must set these parameters to values required by your application. 
Changes to these parameters take effect immediately. A reset is not required.
Changes to settings on some module parameters require that you reset 
the 1769-SM1 module before the new settings take effect. You can reset 
the module by cycling power to the module or by using Parameter 02 - 
[Reset Module]: 
Set the Parameter 02 - [Reset Module] to Reset Module:
Figure 3.18 Reset Screen on an LCD HIM
When you enter 1 = Reset Module, the module will be immediately 
reset. When you enter 2 = Set Defaults, the module will set all module 
parameters to their factory-default settings. The value of this parameter 
will be restored to 0 = Ready after the module is reset.
Parameter
Name
Description
CH1
CH2
CH3
10
27
44
Flt Cfg Logic A 16-bit value sent to the drive for Logic
Command.
11
28
45
Flt Cfg Ref
A 32-bit value (0 – 4294967295) sent to the 
drive as a Reference or Datalink.
Important: If the drive uses a 16-bit 
Reference or 16-bit Datalinks, the most 
significant word of the value should be set to 
zero (0).
12 - 19 29 - 36 46 - 53 Flt Cfg x1 In
or
Flt Cfg x2 In
Resetting the Module
!
ATTENTION: Risk of injury or equipment damage exists. If the 
module is transmitting control I/O to the drive, the drive may fault when 
you reset the module. Determine how your drive will respond before 
resetting a connected module.
Value
Description
0
Ready (Default)
1
Reset Module
2
Set Defaults
Port 2 Device
1769-SM1
Parameter #: 02
Reset Module
1
Reset Module