Rockwell Automation 2706-PRIO_PDH485_PDHP_PDNET_PCNET_PENET_PENET1 InView Communication Module User Manual User Manual
Page 18

Publication 2706-UM017C-EN-P - March 2006
2-2 Install InView Communication Modules
To wire the communication module to the InView display:
1. Disconnect power to InView display.
2. Remove six screws on the power supply cover (on 2706-P4x).
3. Route the serial cable through the cable grip (shipped with
module).
4. Insert the serial wires through the conduit opening on either the
top or the bottom of the InView display.
5. Mount the cable grip to the InView display housing.
6. Tighten the locknut finger-tight and rotate an additional 1/2
turn.
7. Connect the incoming serial wires to the TB1 terminal block.
ATTENTION
Hazardous voltage. Contact with high voltage
may cause death or serious injury. Always
disconnect power to the InView display prior
to servicing.
2706-P42, 2706-P43, 2706-P44
Power Line
Insert the serial wires
with the cable grip into
one of these conduit
openings.
TB1 Terminal Block for serial connection