2-2 Install InView Communication Modules

To wire the communication module to the InView display:

1. Disconnect power to InView display.

2. Remove six screws on the power supply cover (on 2706-P4x).

3. Route the serial cable through the cable grip (shipped with

module).

4. Insert the serial wires through the conduit opening on either the

top or the bottom of the InView display.

5. Mount the cable grip to the InView display housing.

6. Tighten the locknut finger-tight and rotate an additional 1/2

turn.

7. Connect the incoming serial wires to the TB1 terminal block.

ATTENTION

Hazardous voltage. Contact with high voltage
may cause death or serious injury. Always
disconnect power to the InView display prior
to servicing.

2706-P42, 2706-P43, 2706-P44

Power Line

Insert the serial wires
with the cable grip into
one of these conduit
openings.

TB1 Terminal Block for serial connection