Rockwell Automation 2706-PRIO_PDH485_PDHP_PDNET_PCNET_PENET_PENET1 InView Communication Module User Manual User Manual
Page 82

Publication 2706-UM017C-EN-P - March 2006
4-32 Application Guide
EtherNet/IP Tag Setup
• Message Trigger Address. The controller address that triggers a
message to display. This toggles between 0 and 1 in the
controller.
• Message Data Address. The starting address of the message data
displayed. The message data contains the trigger command that
the InView display recognizes (^T[message number]^M ).
• Message Array Size. The size of the array (16 to 80 characters for
SLC 5/05 controller) containing the message data. The maximum
array size is dependent on the controller and must be an even
integer.
• Variable Trigger Address. The controller address that triggers a
message variable to display. This toggles between 0 and 1 in the
controller.
• Variable Data Address. The starting address of the variable data
displayed. The variable data contains the update variable
command that the InView display recognizes
(^V[variable data]\[variable number]^M ).