Rockwell Automation 2706-PRIO_PDH485_PDHP_PDNET_PCNET_PENET_PENET1 InView Communication Module User Manual User Manual

Page 20

Advertising
background image

Publication 2706-UM017C-EN-P - March 2006

2-4 Install InView Communication Modules

2. Open the front of the InView case by turning the latches counter

clockwise and carefully lower the front of the case.

3. Install the Communication Kit (2706-P_K) to the mounting plate

located near TB1 using the supplied standoffs and screws.

4. Torque the screws to 0.68 Nm (6 in-lbs).

Wire Communication Kit to
2706-P72, 2706-P74,
2706-P92 and 2706-P94
Displays

The power to the communication module is provided by the InView
display (series C).

To wire the communication module to the InView display:

1. Connect the serial wires to the TB1 terminal block in the InView

display.

2. Route the customer supplied network cable through the cable

grip and locknut that is provided.

3. Connect the customer supplied network cable to the

Communication Kit.

Verify that there is adequate slack in the cable by making a loop
of cable inside the InView case.

TB1

To TB1

To Controller

(Customer Supplied
Cable)

TIP

The 2706-P_K communication kits are powered
through the serial cable by the display (series C).

Black (GND)1

Red (PWR, +5V)2

Orange (TX)3

Brown (RX)4

5
6
7
8

Advertising