The DeviceNet Interface

1-3

Connecting Your DeviceNet Cable

To attach a plugable, open style, screw-connector to the DeviceNet
cable:

1. Strip 65 mm (2.6 in.) to 75 mm (2.96 in.) of the outer jacket from

the end of the cable, leaving no more than 6.4mm (0.25 in.) of the
braided shield exposed.

Figure 1.2

Exposing the braided shield

2. Wrap the end of the cable with 38 mm (1.5 in.) of shrink wrap,

covering part of the exposed wires and part of the outer jacket.

Figure 1.3

Adding shrink wrap

3. Strip 8.1 mm (0.32 in.) of the insulation from the end of each of

the insulated wire.

Note: Be careful not to nick, cut, or otherwise damage the

individual strands of wire.

Trim the last 6.5 mm (0.26 in.) of the bare wires so that the outside
dimension does not exceed 0.17 mm (0.045 in.).

Figure 1.4

Exposing wire stands

Outer Jacket

Braided Shield

6.4 mm

(0.25 in)

Outer Jacket

Shrink Wrap

38 mm

(1.5 in)

Outer Jacket

Shrink Wrap

8.1 mm

(0.32 in)

Advertising