Position limit state – Rockwell Automation 2098-IPD-020-DN Ultra5000 Series Intelligent Positioning Drives with DeviceNet Reference Manual User Manual

Page 48

Advertising
background image

Publication 2098-RM002A-EN-P – October 2001

4-24

Programming Reference

34

Get

Position Limit

State

USINT

1

State of the position limit function.

0 = Disabled – Position Limits are not being

monitored.

1 = Enabling – The drive is transitioning from the

Disabled state to Running.

2 = Running – The drive is monitoring position

limits.

3 = Stopping – The drive has detected a limit

violation and is decelerating the motor.

4 = Stopped – The motor has been stopped in

response to a limit violation. The drive will not

allow any commanded motion until the Position

Limits are reset.

5 = Resetting – The drive is transitioning from the

Stopped state to Running.

35

Get

Position Limit

Flags

DWORD

4

Indicates which position limit violation(s) have

been detected.

Bit 0 = Positive Soft Limit

Bit 4 = Positive Hard Limit

Bit 8 = Positive Motor Limit

Bit 16 = Negative Soft Limit

Bit 20 = Negative Hard Limit

Bit 24 = Position Motor Limit

36

Set

Jog Forward

Command

USINT

1

Spins the motor at the Jog Program Velocity -

Parameter 40 in the forward direction.

0 = No Action (default)

1 = Execute Command

37

Set

Jog Reverse

Command

USINT

1

Spins the motor at the Jog Program Velocity -

Parameter 40 in the reverse direction.

0 = No Action (default)

1 = Execute Command

38

Set

Jog Stop

Command

USINT

1

Brings the motor to a stop, using the Jog Program

Decel - Parameter 42 rate.

0 = No Action (default)

1 = Execute Command

39

Set

Jog Abort

Command

USINT

1

Brings the motor to an immediate stop.

0 = No Action (default)

1 = Execute Command

40

Set

Jog Program

Velocity

REAL

4

cnts/ sec

The commanded motor velocity when the drive is

jogging. Not saved in non-volatile memory.

Range: -3.4e10 to 3.4e10

Default: 0

41

Set

Jog Program

Accel

REAL

4

cnts/
sec

2

The acceleration rate used when ramping-up to

the Jog Program Velocity. Not saved in

non-volatile memory.

Range: 0 to 3.4e10

Default: 0

Parameter Object,

Instances ID 1- 340
Parameter

Instance

Access

Rule

Parameter

Name

Data

Type

Data

Size

(Bytes)

Units /

Scale

Description