Publication 2098-RM002A-EN-P – October 2001

4-22

Programming Reference

28

Set

Position Hard

Limits

USINT

1

Enables or disables detection of hard limit

violations. The Position Limits (see Enable

Position Limit - Parameter 22) must also be

enabled for hard limit violations to be detected.

The inputs to use for positive and negative hard

limits must be set (see Parameters 32 and 33

below) for the hard limits to be detected. Not

saved in non-volatile memory.

0 = Disable (default)

1 = Enable

Note: Hard limits are enabled on power-up if

either hard limit is assigned.

29

Set

Position Motor

Limits

USINT

1

Enables or disables detection of motor integral

limit violations. The Position Limits (see Enable

Position Limit - Parameter 22) must also be

enabled for motor limit violations to be detected.

The motor limits will only work when using a

motor that supports integral limits (see Parameter

249). Not saved in non-volatile memory.

0 = Disable (default)

1 = Enable

Note: Motor limits are enabled on power-up if

Integral Limits - Parameter 249 are enabled on

the motor.

30

Set

Position Positive

Soft Limit

DINT

4

cnts

The position, in counts, when a positive soft limit

violation will be detected by the drive. This is the

point where the drive will begin decelerating the

axis.

Range: -2147483648 to 2147483647

Default: 0

31

Set

Position Negative

Soft Limit

DINT

4

cnts

The position, in counts, when a negative soft limit

violation will be detected by the drive. This is the

point where the drive will begin decelerating the

axis.

Range: -2147483648 to 2147483647

Default: 0

Parameter Object,

Instances ID 1- 340
Parameter

Instance

Access

Rule

Parameter

Name

Data

Type

Data

Size

(Bytes)

Units /

Scale

Description