Publication 2098-RM002A-EN-P – October 2001

Programming Reference

4-43

191

Set

DAC 2 Offset

REAL

4

Volts

A value added to the scaled voltage value.

Range: -3.4e10 to 3.4e10

Default: 0

192

Set

Manual DAC 2

Value

REAL

4

Volts

The voltage value input to the Analog Output 2

when in Manual mode before the Scaled and

Offset values are applied. Not saved in

non-volatile memory.

Range: -3.4e10 to 3.4e10

Default: 0

193

Get

DAC 2 Output

REAL

4

Volts

The Analog Output 2 output voltage value after

the DAC 2 Scale and DAC 2 Offset values are

applied.

194

Set

Clear Faults

USINT

1

Clears all drive faults.

0 = No Action (default)

1 = Execute Command

195

Set

User Current

Fault Limit

REAL

4

Amps

The current level that will generate a fault when

exceeded by the average current level. The drive

always protects itself and the motor from average

currents that exceed their ratings. This value is

only needed if a lower average current fault is

desired (For example, if another part of a machine

would overheat).

Range: 0 to 3.4e10

Default: 0

196

Set

User Current

Fault

USINT

1

Determines if the User Current fault detection is

enabled (turned on) or disabled.

0 = Disable (default)

1 = Enable

197

Set

User Velocity

Fault Limit

REAL

4

cnts/ sec

The minimum velocity which causes the User

Velocity fault. The drive always protects the

motor from exceeding its ratings. This value is

only needed if a lower velocity fault is desired.

(For example, if another part of a machine could

be damaged.)

Range: 0 to 3.4e10

Default: 0

198

Set

User Velocity

Fault

USINT

4

Determines if the User Velocity fault detection is

enabled (turned on) or disabled.

0 = Disable (default)

1 = Enable

199

Set

Velocity Error

Limit

REAL

4

cnts/ sec

The minimum velocity error that triggers the

Velocity Error fault.

Range: 0 to 3.4e10

Default: 80000

200

Set

Velocity Error

Delay

REAL

4

msec

The minimum time which the velocity error must

be greater than the Velocity Error Limit to cause a

Velocity Error fault.

Range: 0 to 3.4e10

Default: 1000

Parameter Object,

Instances ID 1- 340
Parameter

Instance

Access

Rule

Parameter

Name

Data

Type

Data

Size

(Bytes)

Units /

Scale

Description