Publication 2098-RM002A-EN-P – October 2001

Programming Reference

4-19

8

Set

I/O Receive

Select

USINT

1

Selects the output (consumed) assembly that is

updated when a polled I/O message is received

by the drive. If the value is modified, the user has

to either, close any existing I/O messaging

connection(s), power cycle the drive, reset the

drive, or remove and reapply DeviceNet power for

the drive to use the modified value. Refer to the

Assembly Object for information on the data

format.

0 = No Data Consumed

1 = Assembly Instance 1 (default)

2 = Assembly Instance 2

3 = Assembly Instance 3

4 = Assembly Instance 4

5 = Assembly Instance 5

6 = Assembly Instance 6

7 = Assembly Instance 7

8 = Assembly Instance 8

Automatically saved in non-volatile storage.

9

Set

I/O Transmit

(Xmit) Select

USINT

1

Selects the input (produced) assembly that is

transmitted by the drive over a polled I/O

messaging connection. If the value is modified,

the user has to either, close any existing I/O

messaging connection(s), power cycle the drive,

reset the drive, or remove and reapply DeviceNet

power for the drive to use the modified value.

Refer to the Assembly Object for information on

the data format.

0 = No Data Produced

1 = Assembly Instance 9 (default)

2 = Assembly Instance 10

3 = Assembly Instance 11

4 = Assembly Instance 12

5 = Assembly Instance 13

6 = Assembly Instance 14

7 = Assembly Instance 15

8 = Assembly Instance 16

Automatically saved in non-volatile storage.

10

Set

Axis Enable

Command

USINT

1

Enable the drive.

0 = No Action (default)

1 = Execute Command

11

Set

Disable Axis

Command

USINT

1

Disable the drive.

0 = No Action (default)

1 = Execute Command

12

Set

Reset Drive

USINT

1

Reset the drive.

0 = No Action (default)

1 = Execute Command

13

Set

Save Parameter

Values

USINT

1

Save parameters in non-volatile storage.

0 = No Action (default)

1 = Execute Command

Parameter Object,

Instances ID 1- 340
Parameter

Instance

Access

Rule

Parameter

Name

Data

Type

Data

Size

(Bytes)

Units /

Scale

Description