Rockwell Automation 2098-IPD-020-DN Ultra5000 Series Intelligent Positioning Drives with DeviceNet Reference Manual User Manual

Page 64

Advertising
background image

Publication 2098-RM002A-EN-P – October 2001

4-40

Programming Reference

173

Set

Output 8 State

USINT

1

The current state, or condition, of the digital

output. Not saved in non-volatile memory.

0 = Off (default)

1 = On

174

Set

ADC 1 Scale

REAL

4

A multiplier applied to the voltage read at analog

input 1.

Range: -3.4e10 to 3.4e10

Default: 1

175

Set

ADC 1 Offset

REAL

4

Volts

A value added to the multiplied ADC 1 input.

Range: -3.4e10 to 3.4e10

Default: 0

176

Get

ADC 1 Input

REAL

4

Volts

The scaled value of analog input 1. This value

equals the voltage read at the analog input

multiplied by the gain value, summed with the

offset.

177

Get

ADC 1 Output

REAL

4

Volts

The unscaled value of analog input 1. This value

equals the voltage read at the analog input.

178

Set

ADC 2 Scale

REAL

4

A multiplier applied to the voltage read at analog

input 2.

Range: -3.4e10 to 3.4e10

Default: 1

179

Set

ADC 2 Offset

REAL

4

Volts

A value added to the multiplied ADC 2 input.

Range: -3.4e10 to 3.4e10

Default: 0

180

Get

ADC 2 Input

REAL

4

Volts

The scaled value of analog input 2. This value

equals the voltage read at the analog input

multiplied by the gain value, summed with the

offset.

181

Get

ADC 2 Output

REAL

4

Volts

The unscaled value of analog input 2. This value

equals the voltage read at the analog input.

182

Set

DAC 1 Mode

USINT

1

Selects on the following:

0 = Manual (default) - The voltage at the output is

determined by the Manual DAC 1 Value setting of

the output, along with its scale and offset.

1 = Auto - The voltage at the output is determined

by the DAC 1 Source setting along with its scale

and offset.

Parameter Object,

Instances ID 1- 340
Parameter

Instance

Access

Rule

Parameter

Name

Data

Type

Data

Size

(Bytes)

Units /

Scale

Description