Publication 2098-RM002A-EN-P – October 2001

Programming Reference

4-41

183

Set

DAC 1 Source

USINT

1

Selects the signal used for the DAC 1 output

voltage when DAC 1 Mode is set to Auto mode.

0 = Unassigned (default)

1 = Preg Command Pos

2 = Preg Command Vel

3 = Preg Feedbck Pos

4 = Preg Error

5 = Preg Output

6 = Preg Tune Cmd

7 = Preg Tune Fdbck

8 = Vreg Command Vel

9 = Vreg Command Acc

10 = Vreg Fdbk Vel

11 = Vreg Error

12 = Vreg Output

13 = Vreg Tune Cmd

14 = Vreg Tune Fdbk

15 = Shaft Position

16 = Shaft Angle

17 = Sine (Ireg)

18 = Cosine (Ireg)

19 = Ireg Loop Gain

20 = Average Current

21 = U Phase Current

22 = W Phase Current

23 = U Phase Voltage

24 = V Phase Voltage

25 = W Phase Voltage

26 = Torque Command

27 = Torque Feedback

28 = Torque Error

29 = Torque Output

30 = Field Feedback

31 = Field Error

32 = Field Output

184

Set

DAC 1 Scale

REAL

4

A multiplier applied to signal selected by the DAC

1 Source to obtain a scaled voltage value that is

added to the DAC 1 Offset to obtain the DAC 1

output voltage.

Range: -3.4e10 to 3.4e10

Default: 1

185

Set

DAC 1 Offset

REAL

4

Volts

A value added to the scaled voltage value.

Range: -3.4e10 to 3.4e10

Default: 0

186

Set

Manual DAC 1

Value

REAL

4

Volts

The voltage value input to the Analog Output 1

when in Manual mode before the Scaled and

Offset values are applied. Not saved in

non-volatile memory.

Range: -3.4e10 to 3.4e10

Default: 0

Parameter Object,

Instances ID 1- 340
Parameter

Instance

Access

Rule

Parameter

Name

Data

Type

Data

Size

(Bytes)

Units /

Scale

Description