Set

Ratchet Positive

Mode

BYTE

1

Bit 0 = Ignore Positive Input - Positive direction

master encoder input will generate NO motor

movement.

Bit 1 = Negate Positive Input - Master encoder

input in a positive direction will generate motor

movement in a negative direction.

Note: Selecting "Ignore Positive Input", above,

overrides this selection.

Bit 2 = Buffer Positive Input - Positive direction

master encoder input is accumulated in a buffer

without generating motor movement.

Note: This selection will often be used together

with "Unbuffer Negative Input", above.

Bit 3 = Unbuffer Positive Input - Positive direction

master encoder input will be used first to reduce

the accumulated negative directional buffer then,

only after this buffer is reduced to zero, will

generate motor movement in the positive

direction.

Note: This assumes "Buffer Positive Input",

above, is not selected

Default = 0.

143

Get

Motor Encoder

Output

DINT

4

cnts

The motor encoder's output.

144

Get

Master Encoder

Output

DINT

4

cnts

The master encoder's output.

145

Get

Ratchet State

USINT

1

Provides the state of the ratchet.

0 = Disable

1 = Enable

146

Get

Ratchet Buffer

DINT

4

cnts

The accumulated value stored in the buffer when

negative or positive input is set to buffer and/or

unbuffer. This value is automatically re-set to zero

at drive power up.

147

Get

Ratchet Output

DINT

4

cnts

The position generated by the ratchet. This value

is automatically re-set to zero at drive power up.

148

Get

Ratchet Position

DINT

4

cnts

The position generated by the ratchet. This value

is automatically reset to zero at power up.

149

Get

Ratchet Velocity

REAL

4

cnts/ sec

The velocity command generated by the ratchet.

150

Get

Input 1 State

USINT

1

The current state, or condition, of the digital

input.

0 = Off

1 = On

Parameter Object,

Instances ID 1- 340
Parameter

Instance

Access

Rule

Parameter

Name

Data

Type

Data

Size

(Bytes)

Units /

Scale

Description