The DeviceNet Interface

Figure 1.7

Data Rate Rotary Switch

4. Apply power to the drive.

5. Observe the module status LED.

6. Observe the network status LED.

If the module status LED:

Then:

Is not steady green

Refer to Troubleshooting DeviceNet Drives

on page 5-1.

Is steady green

The drive is ready. Go to step 6.

If the network status LED:

Then:

Is off

Establishing communication with

network (wait for flashing or

steady green).

Is not flashing or steady green

Refer to Troubleshooting

DeviceNet Drives on page 5-1.

Is flashing or steady green

Communication is ready. Go to

Chapter 2.

Use the Data Rate rotary switch on the DeviceNet
panel of the drive to set the data rate.