To a stop, using the jog program, Decel - parameter 42 rate – Rockwell Automation 2098-IPD-020-DN Ultra5000 Series Intelligent Positioning Drives with DeviceNet Reference Manual User Manual

Page 49

Advertising
background image

Publication 2098-RM002A-EN-P – October 2001

Programming Reference

4-25

42

Set

Jog Program

Decel

REAL

4

cnts/ sec

2

The deceleration rate used when ramping-down

from Jog Program Velocity to zero. Not saved in

non-volatile memory.

Range: 0 to 3.4e10

Default: 0

43

Get

Jog State

USINT

1

Describes the relation between the Jog Program

Velocity and Jog Current Velocity, as follows:

0 = Locked, when Jog Current Velocity equals Jog

Program Velocity.

1 = Seeking, when the jog is accelerating or

decelerating.

44

Get

Jog Mode

USINT

1

Describes the direction of the drive's jog, as

follows:

0 = Stopped, when not jogging

1 = Forward, when jogging forward

2 = Reverse, when jogging in reverse

45

Get

Jog Current

Position

DINT

4

cnts

The position generated by the current jog. This

value is automatically re-set to zero at drive

power up.

46

Get

Jog Current

Velocity

REAL

4

cnts/ sec

The velocity command generated by the current

jog.

47

Get

Jog Current

Accel

REAL

4

cnts/ sec

2

The acceleration command generated by the

current jog.

48

Set

Move Start

Command

USINT

1

Starts a trapezoidal move defined by the Move

Program Distance, Move Program Velocity, Move

Program Accel, and Move Program Decel (see

Parameters 51, 52, 53, and 54 below).

0 = No Action (default)

1 = Execute Command

49

Set

Move Stop

Command

USINT

1

Brings the motor to a stop, using the Move

Program Decel.

0 = No Action (default)

1 = Execute Command

50

Set

Move Abort

Command

USINT

1

Brings the motor to an immediate stop.

0 = No Action (default)

1 = Execute Command to an immediate stop.

51

Set

Move Program

Distance

DINT

4

cnts

The distance that the motor is to move when a

Move Start Command is executed. Not saved in

non-volatile memory.

Range: -2147483648 to 2147483647

Default: 0

52

Set

Move Program

Velocity

REAL

4

cnts/ sec

The commanded motor velocity during a move.

Range: -3.4e10 to 3.4e10 Not saved in

non-volatile memory.

Default: 0

Parameter Object,

Instances ID 1- 340
Parameter

Instance

Access

Rule

Parameter

Name

Data

Type

Data

Size

(Bytes)

Units /

Scale

Description

Advertising