Rockwell Automation 9303 DRIVE TOOLS32 GETTING STARTED User Manual

Page 68

Advertising
background image

6-4

Setting Up a ControlNet Direct Communications System

Publication 9303-5.13 – March 1998

Mapping the Configured Driver(s) to the KTPort Value

To map the configured driver(s) to the KTPort value, you need to:

1.

From the Communications menu, select Configure Client Applications.
The Configure Client Applications dialog box appears.

2.

Choose an unused KT:0 field to map the ControlNet device to.

Important: When you use the Communication Setup option from within any
of the DriveTools32 applications, you need to enter the RSLinx KT:0 number
(i.e., 1 – 8) to which you just mapped the ControlNet device. Enter this number
in the Enter mapping KT(X) Port # to use field in the Communication Setup
dialog box.

3.

Use the drop box for the field to map the configured driver to the port.

4.

Click OK or Apply.

Advertising