Rockwell Automation Publication 2080-UM002F-EN-E - December 2013

91

Motion Control with PTO and PWM Chapter 7

Edit Axis Configuration

General Parameters

1.

On the axis configuration tree, click General.
The <Axis Name> - General properties tab appears.

2.

Edit General parameters. You can refer to the table for a description of the
general configuration parameters for a motion axis.

TIP

To help you edit these motion properties, see

Edit Axis Configuration on

page 91

. You can also learn more about axis configuration parameters.

IMPORTANT

To edit these general parameters, you can refer to

Input and Output

Signals on page 64

for more information about fixed and configurable

outputs.

General Parameters

Parameter

Description and Values

Axis Name

User defined. Provides a name for the motion axis.

PTO Channel

Shows the list of available PTO channels.

Pulse output

Presents the logical variable name of the Direction Output channel based
on the PTO channel value that has been assigned.

Direction output

Presents the logical variable name of the Direction Output channel based
on the PTO channel value that has been assigned.

Drive Enable Output

Servo On Output Enable flag. Check the option box to enable.

- Output

The list of available digital output variables that can be assigned as
servo/drive output.

- Active Level

Set as High (default) or Low.

In-position Input

Check the option box to enable in-position input monitoring.

- Input

List of digital input variables for in-position input monitoring.
Select an input.

Advertising