Rockwell Automation 2080-LC50 Micro830 and Micro850 Programmable Controllers User Manual User Manual

Page 131

Advertising
background image

Rockwell Automation Publication 2080-UM002F-EN-E - December 2013

115

Use the High-Speed Counter and Programmable Limit Switch Chapter 8

Micro830/Micro850 24-point Controller HSC Input Wiring Mapping

Modes of Operation

Input 0 (HSC0)
Input 2 (HSC1)
Input 4 (HSC2)
Input 6 (HSC3)

Input 1 (HSC0)
Input 3 (HSC1)
Input 5 (HSC2)
Input 7 (HSC3)

Input 2 (HSC0)
Input 6 (HSC2)

Input 3 (HSC0)
Input 7 (HSC2)

Mode Value in User
Program

Counter with Internal Direction
(mode 1a)

Count Up

Not Used

0

Counter with Internal
Direction, External Reset and
Hold (mode 1b)

Count Up

Not Used

Reset

Hold

1

Counter with External
Direction (mode 2a)

Count Up/Down

Direction

Not Used

2

Counter with External
Direction, Reset and Hold
(mode 2b)

Count Up/Down

Direction

Reset

Hold

3

Two Input Counter (mode 3a)

Count Up

Count Down

Not Used

4

Two Input Counter with
External Reset and Hold (mode
3b)

Count Up

Count Down

Reset

Hold

5

Quadrature Counter (mode 4a) A Type input

B Type input

Not Used

6

Quadrature Counter with
External Reset and Hold (mode
4b)

A Type input

B Type input

Z Type Reset

Hold

7

Quadrature X4 Counter
(mode 5a)

A Type input

B Type input

Not Used

8

Quadrature X4 Counter with
External Reset and Hold

A Type input

B Type input

Z Type Reset

Hold

9

Micro830/Micro850 48-point Controller HSC Input Wiring Mapping

Modes of Operation

Input 0 (HSC0)
Input 2 (HSC1)
Input 4 (HSC2)
Input 6 (HSC3)
Input 8 (HSC4)
Input 10 (HSC5)

Input 1 (HSC0)
Input 3 (HSC1)
Input 5 (HSC2)
Input 7 (HSC3)
Input 9 (HSC4)
Input 11 (HSC5)

Input 2 (HSC0)
Input 6 (HSC2)
Input 10 (HSC4)

Input 3 (HSC0)
Input 7 (HSC2)
Input 11 (HSC4)

Mode Value in User
Program

Counter with Internal Direction
(mode 1a)

Count Up

Not Used

0

Counter with Internal
Direction, External Reset and
Hold (mode 1b)

Count Up

Not Used

Reset

Hold

1

Counter with External
Direction (mode 2a)

Count Up/Down

Direction

Not Used

2

Counter with External
Direction, Reset and Hold
(mode 2b)

Count Up/Down

Direction

Reset

Hold

3

Two Input Counter (mode 3a)

Count Up

Count Down

Not Used

4

Two Input Counter with
External Reset and Hold (mode
3b)

Count Up

Count Down

Reset

Hold

5

Quadrature Counter (mode 4a) A Type input

B Type input

Not Used

6

Advertising