Rockwell Automation Publication 2080-UM002F-EN-E - December 2013

65

Motion Control with PTO and PWM Chapter 7

Motion Wiring Input/Output Description

Motion Signals

Input/Output

Description

Uniqueness

PTO pulse

OUTPUT

PTO pulse from the embedded fast output, to
be connected to Drive PTO input.

Not Shared

PTO direction

OUTPUT

PTO pulse direction indication, to be
connected to Drive Direction input.

Not Shared

Servo/Drive On

OUTPUT

The control signal used to
activate/deactivate Servo/Drive.
This signal becomes Active when
MC_Power(on) is commanded.

Can be shared
with more
than one drive

Lower (Negative)
Limit switch

INPUT

The input for hardware negative limit switch,
to be connected to mechanical/electrical
negative limit sensor.

Not Shared

Upper (Positive)
Limit switch

INPUT

The input for hardware positive limit switch,
to be connected to mechanical/electrical
positive limit sensor.

Not Shared

Absolute Home
switch

INPUT

The input for hardware home switch (sensor),
to be connected to mechanical/electrical
home sensor.

Not Shared

Touch Probe Input
switch

INPUT

The input for hardware touch probe signal, to
be used with Motion MC_TouchProbe and
MC_AbortTrigger function blocks to capture
axis commanded position during the motion
path.

Not Shared

Servo/Drive Ready

INPUT

The input signal that indicates Servo/Drive is
ready to receive PTO pulse and direction
signal from controller.
No moving function blocks can be issued to
an axis before the axis has this signal ready if
this signal is Enabled in the motion axis
configuration or axis properties page.

Can be shared
with more
than one drive

In-Position signal
(from Servo/motor)

INPUT

The input signal that indicates the moving
part is in the commanded position. This
signal has to be Active after the moving part
reaches the commanded position for
MoveAbsolute and MoveRelative function
blocks.
For MoveAbsolute and MoveRelative
function blocks, when In_Position is enabled,
the controller will report an error
(EP_MC_MECHAN_ERR) if the signal is not
active within five seconds when the last PTO
pulse sent out.

Not Shared

Home Marker

INPUT

This signal is the zero pulse signal from the
motor encoder. This signal can be used for
fine homing sequence to improve the homing
accuracy.

Not Shared