Rockwell Automation Publication 2080-UM002F-EN-E - December 2013

95

Motion Control with PTO and PWM Chapter 7

3.

Click Dynamics. The <Axis Name> - Dynamics tab appears. Edit the
Dynamics parameters based on the table below.

Dynamics Parameters

Parameter

Values

Start/Stop Velocity

(1)

(2)

The range is based on Motor and Load parameters (See

Motor and

Load Parameters on page 93

) using:

Range 1…100,000 pulse/sec
Default: 300 rpm
For example, you can configure the value from 0.005…500 mm/s for
200 pulses per revolution and units of 1 mm per revolution.

(3)

Rpm value is automatically populated when a value in user units is
specified, but the user can also initially enter an rpm value.
Start/stop velocity should not be greater than maximum velocity.

Start/Stop Velocity in
rpm

(1) (2)

Max Velocity

(1) (2)

The range is based on Motor and Load parameters (See

Motor and

Load Parameters on page 93

) using:

Range: 1…10,000,000 pulse/sec.
Default: 100,000.0 pulse/sec

Max Acceleration

(1)

The range is based on Motor and Load parameters (See

Motor and

Load Parameters on page 93

) using:

Range: 1…10,000,000 pulse/sec

2

Default: 10,000,000 pulse/sec

2

Max Deceleration

(1)

The range is based on Motor and Load parameters (See

Motor and

Load Parameters on page 93

) using:

Range: 1…100,000 pulse/sec

2

Default: 10,000,000 pulse/sec

2

Max Jerk

(1)

The range is based on Motor and Load parameters (See

Motor and

Load Parameters on page 93

) using:

Range: 0…10,000,000 pulse/sec

3

Default: 10,000,000 pulse/sec

3

Emergency Stop Profile

Defines stop type, velocity, deceleration and jerk values.

Stop Type

Set as Deceleration Stop (default) or Immediate Stop.