Overview of the DL40 Plus

1–2

Publication 2706-6.1

RS-485/RS-232 Communications

Both the Remote I/O and Parallel Port versions have RS-485 and
RS-232 ports. You can configure these ports for Programmer, DL
Slave or Open Protocol communications (see table below). Port
settings are modified through the Ports menu in the Offline
Programming software or the Onboard Editor. You select a
communication option under the Port Use submenu.

The RS-232 port always communicates with the Offline
Programming Software regardless of the configured mode. Open
Protocol or DL Slave operation can occur on either the RS-232 or
RS-485 port.

If the RS-485 port is configured for Open protocol, you cannot
configure the RS-232 port for the same protocol. Instead, an
information message reports an invalid port configuration.

Con

urat ons

escr pt on

Plus Port

Communication/Printing Options

Configurations

Description

DL40 Plus Port

Programmer

Open Protocol

Slave

Printing

Offline Programming

RS–485

1

Offline Programming

and Serial Printing

RS–232

RS-232 Offline Programming

RS–485

2

RS-232 Offline Programming

and RS-485 Message Triggering

RS–232

3

RS-232 Offline Programming

RS–485

3

RS-232 Offline Programming

RS-485 Slave Communications

RS–232

RS-485 Offline Programming

RS–485

4

RS-485 Offline Programming

RS-232 Message Triggering

RS–232

RS-485 Slave Communications

RS–485

5

RS-485 Slave Communications

RS-232 Message Triggering

RS–232

RS-485 Offline Programming

RS–485

6

RS-485 Offline Programming

RS-232 Slave Communications

RS–232

RS-485 Message Triggering

RS–485

7

RS-485 Message Triggering

RS-232 Slave Communications

RS–232

Note: Open protocol is a serial ASCII based format for triggering
messages stored in the DL40 Plus displays. Open protocol supports
message triggers with or without variable data over the RS-232 or
RS-485 serial ports.