Rockwell Automation 2706-LV2P_LV2R_LV4P_LV4R DL40 PLUS USER MANUAL User Manual

Page 53

Advertising
background image

Using Special Messages

3–8

Publication 2706-6.1

915 (or 15) Stop Special Messages/Resume Run Mode

If one of the following special messages is running, special message
915 immediately terminates that message and clears the display.
Does not affect special messages in the queue.

906

Print Historical Events Stack – Chronological
Order

907

Print Historical Events Stack – Frequency of
Occurrence

908

View Historical Events Stack

910

Interactive Clock Setting

911

Set Clock with Variable Data

914

View Display Parameters

916

Set Display Intensity

916 (or 16) Set Display Intensity

Sets intensity of the DL40 Plus display to a value between 0 and
100% of full intensity. Default value after reset or power–up is 75%.

This message contains a single 16 bit variable with a valid domain of
0 to 100, which represents the desired display intensity level.

The DL40 Plus shows:

% INTENSITY IS__ __ __ __

Only allows changes in Message/Variable and
Message/Variable/Slave Run Modes since Message List and Bit
Trigger Run Modes do not support variables.

This message is put at the end of the queue and only runs after all
messages before it have run.

This message terminates and retains new settings if either:

no new setting is received for 5 seconds

special message 915 is triggered