2–7

Publication 2706-6.1

Change Formatted Variable

[CTRL][F]

Use

[CTRL][F]

to change the formatting parameters of a variable. To

do so, place the cursor under the symbol for the variable you want to
change, then press

[CTRL][F]

. You are prompted to modify one or

more of the 3 formatting parameters described below:

Parameter

Acceptable values

Variable Size

1 to 7 (including decimal point)

Decimal Point Position
(number of places after the
decimal point)

0 to 6 (the maximum value is one less than the
variable size selected above)

Suppress Zeroes
(appearing in front of the
first significant digit)

Y(es) or N(o)

Insert ASCII or BCD Variable

[CTRL][W]

You can send a single word ASCII or BCD variable to insert in a
message. Use

[CTRL][W]

to specify the insertion position. The

software will insert the symbol for an ASCII or BCD variable (↕).

BCD data consists of 4 digits per word and ASCII data consists of 2
characters per word.

Variables can be strung together to form compound variables up to
20 ASCII or 40 BCD characters in any combination, not to exceed
10 words.