Remote I/O Application Examples

E–12

Publication 2706-807

Triggerring Messages Using Discrete I/O - PLC5 Example
(Bit Trigger Run Mode)

PLC5 at Rack #1, Group #0
Trigger message #1 here:
Format: 0 = Disabled

1 = Enabled. Trigger message

Move
Source

0

0<

Dest

N9:2

1<

MOV

0000

Bit Field Distributor
Source

N9:2

1<

Source Bit

0

Dest

O:011

1<

Dest Bit

0

Length

1

BTD

0001

0002

0003

0004

Trigger message #2 here:
Format: 0 = Disabled

1 = Enabled. Trigger message

Move
Source

0

0<

Dest

N9:3

0<

MOV

Bit Field Distributor
Source

N9:3

0<

Source Bit

0

Dest

O:011

1<

Dest Bit

1

Length

1

BTD

Enter priority message number to trigger here:
(The priority message occupies word 0, bits 0–13
in the output image table.)

Move
Source

N9:20

4<

Dest

N9:20

4<

MOV

Masked Move
Source

N9:20

4<

Mask

0FFFH

4095<

Dest

O:010

–31856<

MVM

0005

<END>

0006