Remote I/O Communications
8–7
Publication 2706-6.1
Slave Address
Slave address for Message/Variable/Slave run mode. Data is in same
format as message number. Variable data cannot be used.
Variable Data
Callouts
Acceptable Values
[CTRL][V]
0 to 9999 in BCD format (+ / -, depending on BCD Sign Bit)
-32,768 to +32,767 for signed (twos complement) binary
[CTRL][W]
0 to 99 for ASCII - 8-bit (2 per word) first variable in high byte
0 to 9999 for BCD - 4-bit (4 per word) first variable in high nibble of
high byte
Variable Data (+)
Can only be used in the Message/Variable run mode.
Variable Data Number
For Discrete I/O,
1
/
4
rack only. Binary number - sets position of
variable data in message:
0
=
First variable in the message
1
=
Second variable in the message
2
=
Third variable in the message
3
=
Fourth variable in the message