Hex Example:

Where:

Serial Port Communications

6–7

Publication 2706-6.1

Message/Variable Run Mode

In Message/Variable Run modes, messages are triggered using the
following forms:

Data

Acceptable Values

Msg. Number

1 to 4 digits (1 to 9999)

DL40 Plus

Address

1 to 3 digits (0 to 127)
127 = all DL40 Plus displays on RS-485RS–232 link

[CTRL][T]

Msg.

Number

Backslash

( \ )

DL40 Plus

Address

Return

(CR)[

]

\14

\31

(Hex 31 = 1)

\5C

(Hex 5C = \)

\31

(Hex 31 = 1)

\0D

(Hex 0D = CR)

Note: For the Hex examples refer to Appendix D, ASCII Character
Sets
.

Keyboard entries are performed with standard characters. The
above listed Hex examples refer to non–keyboard entries.

The DL40 Plus address is optional if triggering a message via the
keyboard. If no DL40 Plus address is sent, the message will be
triggered on the DL40 Plus that the keyboard is plugged into. If a
DL40 Plus address is specified, the message will run only if the
address is 127 or if it matches the address of the DL40 Plus that
the keyboard is plugged into. If no DL40 Plus address is sent
when using the RS-485/RS–232 link, the message trigger will be
ignored.

If no DL40 Plus address is sent, the backslash ( \ ) is optional.

If the Remote I/O Port is inactive or faulted, the Last State switch
(number 8 on SW2) must be ON to trigger messages from the
keyboard or via the RS-485/RS–232 Port.