Using Special Messages

3–7

Publication 2706-6.1

913 (or 13) Send Date to PLC (Remote I/O versions only)

Sends date data to the PLC.

This message is put at the end of the queue and only runs after all
messages before it have run. See Chapter 8, Remote I/O
Communications
for examples.

914 (or 14) View Display Parameters

Causes the DL40 Plus to display operating parameters.

Operating Parameters

RS-232 Serial Port Baud Rate
RS-232 Serial Port Parity Setting
RS–232 Address
RS–232 Port Usage
RS-485 Serial Port Baud Rate
RS-485 Serial Port Parity Setting
RS-485 Address
RS-485 Port Usage
DL40 Plus’s Run Mode
Memory Available for Historical Events Stack
Memory Used by Historical Events Stack
DL40 Plus’s Rack Address (Remote I/O version only)
DL40 Plus’s Starting I/O Group (Remote I/O version only)
DL40 Plus’s Rack Size (Remote I/O version only)
Remote I/O Baud Rate (Remote I/O version only)
Block Transfers Enabled (Remote I/O version only)

After the last parameter, the display returns to Run mode.

This message is put at the end of the queue and only runs after all
messages before it have run.

To stop viewing parameters:

trigger Special Message 901, 903, 904, or 915

from keyboard–press

[ESC]

from front panel–press

[MSG ACK]

exit Run mode