Chapter 5 Understanding Report Templates
54
Rockwell Automation Publication RPTEXP-UM001H-EN-P-June 2014
The bar chart fields:
Event Count chart fields:
Item
Description
Value
Event Count
X axis grouping
First non-page grouping parameter
Series
Second non-page grouping
Total Duration chart fields:
Item
Description
Value
Total Duration
X axis grouping
First non-page grouping parameter
Series
Second non-page grouping
The Fault report template displays aggregated data related to faults
of the machinery. It allows you to assess how often and for how long
the faults occurred during the manufacturing process, and provides
links to Event Summary reports concerning faults for a specific work
cell.
Query: Performance.
The fields of the report template grid:
Item
Description
Running Time
The number of seconds the machine was in a running state.
Fault Time
The time when the fault occurred.
Fault Count
The number of faults that occurred in the reporting period.
Fault