Uptime – Rockwell Automation FactoryTalk Report Expert User Guide User Manual

Page 70

Advertising
background image

Chapter 5 Understanding Report Templates

70

Rockwell Automation Publication RPTEXP-UM001H-EN-P-June 2014

Throughput % chart fields:

Item

Description

Value

Throughput %

X axis grouping

First non-page grouping parameter

Series

Second non-page grouping

Realized vs. Ideal Cycle Time chart fields:

Item

Description

Value

Realized Cycle Time, Ideal Cycle Time

X axis grouping

First non-page grouping parameter

Series

Second non-page grouping

Calculations used by Report Expert to obtain values in the resulting
report:

RealizedCycleTime = RunningTime / TotalParts
CycleTimeDiff = IdealCycleTime - RealizedCycleTime
CycleTimeDiff% = -CycleTimeDifference / IdealCycleTime
Throughput% = (TotalParts x IdealCycleTime) / Running

Time

The Uptime report template allows you to assess the production
availability of one or more activity areas. Uptime is a ratio of

running time to available time. Available time may be defined by a
schedule or modified by planned downtime events such as
preventive maintenance. Available time may also be modified by
events such as being starved for parts or being blocked by a
downstream process.

Query: Performance

Uptime

Advertising