Rockwell Automation FactoryTalk Report Expert User Guide User Manual

Page 58

Advertising
background image

Chapter 5 Understanding Report Templates

58

Rockwell Automation Publication RPTEXP-UM001H-EN-P-June 2014

Calculations used by Report Expert to obtain values in the resulting
report:

Uptime % = RunningTime/AvailableTime
Throughput % = (TotalParts x IdealCycleTime) /

RunningTime

Quality % = GoodParts / Total Parts
OEE % = Uptime x Throughput x Quality

Or:

This reduces to:

NOTE

Typically, the OEE calculation will be performed over a time range with
numerous IdealCycleTime values. In this case, the calculation is done for
each unique IdealCycleTime using the GoodParts and AvailableTime

during that IdealCycleTime. Each individual calculation is then
multiplied by its fraction of the TotalAvailableTime

(AvailableTime/TotalAvailableTime) and then summed together.

The following formula illustrates the calculation with multiple
IdealCycleTimes:

where:

• ICT = IdealCycleTime
• GP = GoodParts

Advertising