Rockwell Automation FactoryTalk Report Expert User Guide User Manual

Page 57

Advertising
background image

Understanding Report Templates Chapter 5

Rockwell Automation Publication RPTEXP-UM001H-EN-P-June 2014

57

The fields of the report template grid:

Item

Description

Uptime %

The percentage of available time that the machine was actually

running. The calculation for this field is:
Uptime % = RunningTime/AvailableTime.

Throughput %

The performance of a machine when it is running compared to its

ideal cycle time. The ideal cycle time depends upon the product
being produced and is measured in units of seconds per part. The

calculation for this field is:
Throughput = (TotalParts x IdealCycleTime) / Running Time.

Quality %

The percentage of total parts produced that were of good quality.
The calculation for this field is:

Quality % = GoodParts / Total Parts.

OEE %

The product of Uptime, Throughput, and Quality. The calculation for
this field is:

OEE % = Uptime x Throughput x Quality.

The values of the report template and other report templates to
which the values link using the drillthrough hierarchy:

Click a value in this column:

To display this report template:

Uptime %

Uptime

Throughput %

Throughput

Quality %

Quality

OEE %

Performance

The report template bar charts: OEE %.

The bar chart fields:

Item

Description

Value

OEE %

X axis grouping

First non-page grouping parameter

Series

Second non-page grouping

Advertising