Table 2.2 – Control Key Descriptions

Key

Mode

Function

Program or

Monitor

Allows you to select from a list of possible sources for drive control

signals.

is not active when the drive is running or jogging, and

during Quick Start and self-tuning. See section 6.2 for information on
selecting a control source.

Program or

Monitor

When

is set to

KEYPAD

and the drive is ready, holding

down jogs the motor. The motor stops when

is released.

When jogging, the motor ramps up to

JOG

SPEED

(P.012) at the speed

set by

JOG

ACCEL

/

DECEL

TIME

(P.013). When

is released, the

drive reference ramps down to zero at the same rate.

Program or

Monitor

When

is set to

KEYPAD

and the drive is ready,

applies

power to the motor and allows it to accelerate to the reference.

Program or

Monitor

If the drive is running,

stops the drive as selected by

STOP

MODE

SELECT

(P.114). When the

OIM

is connected and

communicating with the drive,

is always active, regardless of

the setting of

.

If the drive is not running and

is set to

KEYPAD

,

resets

any active faults and alarms. It does not clear the fault and alarm
logs. See chapter 7 for information on resetting faults and alarms.

!

ATTENTION: The user must provide an external,
operator-accessible coast/stop pushbutton at terminals 7 and 8 on
the Regulator board to disable the machine in case of improper
operation. Uncontrolled machine operation can result if this
procedure is not followed. Failure to observe this precaution could
result in severe bodily injury or loss of life.