Rockwell Automation WebPak 3000  User Guide User Manual

Page 64

Advertising
background image

7-6

WebPak 3000 OIM User Guide

Table 7.1 – Possible OIM Responses to “Why is the Drive Not Ready?”

Display

Description

DOWNLOAD

IN

PROGRESS

WebPak CS configuration file download
procedure is in progress or the configuration
parameters are being processed.

COAST

/

DB

STOP

OPEN

The coast/DB stop input (TS 8) is open.

CUSTOMER

INTERLOCK

OPEN

The customer interlock (TS 9) is open.

MEMORY

OPERATION

IS

PROGRESS

Non-volatile memory is being restored.

DRIVE

IS

IN

PROCESS

OF

STOPPING

The drive is in the process of stopping.

THERE

IS

A

DRIVE

FAULT

(

S

)

The drive has one or more active faults.

A

STOP

INPUT

IS

ACTIVE

A keypad stop or the active control source
stop is asserted.

THE

DRIVE

IS

READY

The drive is ready to start.

Table 7.2 – Possible OIM Responses to “Why Did the Drive Stop?”

Display

Description

JOG

WAS

RELEASED

The jog input from the active control source
was released.

CURRENT

LIMIT

STOP

Current limit stop was selected by

STOP

MODE

SELECT

(P.114).

RAMP

STOP

Ramp stop was selected by

STOP

MODE

SELECT

(P.114).

COAST

/

DB

STOP

Coast/DB stop was selected by

STOP

MODE

SELECT

(P.114).

FAULT

STOP

Internal fault stop or normal self-tuning stop.

CUSTOMER

INTERLOCK

OPEN

The customer interlock (TS 9) opened.

COAST

/

DB

STOP

OPEN

The coast/DB stop was asserted (TS 8).

MAIN

CONTACTOR

IS

OPEN

The main contactor opened.

DRIVE

IS

IN

PROCESS

OF

STOPPING

The drive is in the process of stopping.

DRIVE

IS

RUNNING

The drive is running.

DRIVE

IS

JOGGING

The drive is jogging.