Using Quick Start

5-9

TOP

LINE

SPEED

(P.020)

Specifies the
maximum line speed
in feet per minute.

Parameter Range:

0 to 5000

FPM

Default Setting:

500

FPM

Parameter Type:

Configurable

!

ATTENTION: Do not allow the motor to exceed the maximum safe speed
of the motor or driven equipment as determined by the equipment
manufacturer. Failure to observe this precaution could result in bodily
injury.

MOTOR

RATED

ARM

AMPS

(P.008)

Identifies the rated
armature current as
is appears on the
motor nameplate.

Parameter Range:

0 to 3000.0

AMPS

Default Setting:

8.0

AMPS

Parameter Type:

Configurable

!

ATTENTION:

MOTOR

RATED

ARM

AMPS

(P.008) must be less than the

motor rated armature amps or drive current rating listed on the motor
nameplate. If this is configured incorrectly, overcurrent or excess heating
of the motor could result. Failure to observe this precaution could result
in damage to, or destruction of, the equipment.

MOTOR

RATED

ARM

VOLTS

(P.009)

Identifies the rated
armature voltage as it
appears on the motor
nameplate.

Parameter Range:

160 to 1000

VOLTS

Default Setting:

240

VOLTS

Parameter Type:

Configurable

!

ATTENTION: The incorrect configuration of

MOTOR

RATED

ARM

VOLTS

(P.009) can cause an overspeed condition. This parameter must be
configured by a qualified person who understands the significance of
configuring it accurately. Failure to observe this precaution could result
in bodily injury.