2 key indicators – Rockwell Automation WebPak 3000  User Guide User Manual

Page 17

Advertising
background image

Description of the OIM Keypad, Display, and Indicators

2-7

2.2.2 Key Indicators

There are five indicators at the bottom of the screen above the keys. When

is

set to

KEYPAD

, these indicators tell you which setting is selected by the key. If one of

the other control sources is selected, these indicators tell you the setting selected by
that control source.

In figure 2.2, the keys are set to

PROGRAM

and

KEYPAD

. Indicators are described in

table 2.4.

Table 2.4 – Key Indicators

Key Indicator Above

Possible

Indications

Description

PROGRAM

The

OIM

is in program mode.

MONITOR

The

OIM

is in monitor mode.

(blank)

The

OIM

is in a fault, alarm, or diagnostic menu.

FAULT

The Fault Menu is displayed.

ALARM

The Alarm Menu is displayed.

DIAGS

The Diagnostics Menu is displayed.

TERMBLK

The signals at the Regulator board terminal strip control the
drive.

NETWORK

A network is controlling drive operation. Blinks when network
communication is not active.

SERIAL

The drive is controlled through its serial port, typically by the
WebPak CS software.

KEYPAD

The

OIM

keys control drive operation.

Advertising